| Function |
Char |
hex |
dec |
005
card |
Interfaces
1=Vs 2=Va
3=Ms,3a=3d
4=GPS
5=Polar
|
Notes
[1]
separate items on 007, alternating on 005,044
[2]
traditional user channels (Un= command) |
| |
nul |
00 |
0 |
|
|
frame
separator: can't be a tag |
| |
soh |
01 |
1 |
|
|
non-printing
character |
| |
stx |
02 |
2 |
|
|
non-printing
character |
| |
etx |
03 |
3 |
|
|
non-printing
character |
| |
eot |
04 |
4 |
|
|
non-printing
character |
| |
enq |
05 |
5 |
|
|
non-printing
character |
| |
ack |
06 |
6 |
|
|
non-printing
character |
| major
error flag |
bel |
07 |
7 |
|
|
005
displays "!" |
| |
bs |
08 |
8 |
|
|
non-printing
character |
| |
ht |
09 |
9 |
|
|
non-printing
character |
| |
lf |
0A |
10 |
|
|
non-printing
character |
| |
vt |
0B |
11 |
|
|
non-printing
character |
| |
ff |
0C |
12 |
|
|
non-printing
character |
| |
cr |
0D |
13 |
|
|
non-printing
character |
| |
so |
0E |
14 |
|
|
non-printing
character |
| |
si |
0F |
15 |
|
|
non-printing
character |
| |
dle |
10 |
16 |
|
|
non-printing
character |
| |
dc1 |
11 |
17 |
|
|
non-printing
character |
| |
dc2 |
12 |
18 |
|
|
non-printing
character |
| |
dc3 |
13 |
19 |
|
|
non-printing
character |
| |
dc4 |
14 |
20 |
|
|
non-printing
character |
| |
nak |
15 |
21 |
|
|
non-printing
character |
| |
syn |
16 |
22 |
|
|
non-printing
character |
| |
etb |
17 |
23 |
|
|
non-printing
character |
| |
can |
18 |
24 |
|
|
non-printing
character |
| |
em |
19 |
25 |
|
|
non-printing
character |
| |
sub |
1A |
26 |
|
|
non-printing
character |
| |
esc |
1B |
27 |
|
|
non-printing
character |
| |
fs |
1C |
28 |
|
|
non-printing
character |
| |
gs |
1D |
29 |
|
|
non-printing
character |
| |
rs |
1E |
30 |
|
|
non-printing
character |
| |
us |
1F |
31 |
|
|
non-printing
character |
| Tryad
Status 1 |
space |
20 |
32 |
00100000 |
T1 |
T1
only |
| |
! |
21 |
33 |
00100001 |
|
005
treat this as "All indicators". |
| |
" |
22 |
34 |
00100010 |
|
|
| |
# |
23 |
35 |
00100011 |
|
many
Q interfaces use this tag |
| NMEA
data |
$ |
24 |
36 |
00100100 |
T1
or
001>16.2 |
From
inputs & instrument system |
| |
% |
25 |
37 |
00100101 |
|
address
switch setting "E" on most Q interfaces |
| |
& |
26 |
38 |
00100110 |
|
address
switch setting "F" on most Q interfaces |
| |
' |
27 |
39 |
00100111 |
|
|
| |
( |
28 |
40 |
00101000 |
|
|
| |
) |
29 |
41 |
00101001 |
|
|
| Lights |
* |
2A |
42 |
00101010 |
CPU |
displays
value only, set system light level with Option 9 |
| Axial
windspeed |
+ |
2B |
43 |
00101011 |
3D
sonic MHU |
3D
mastheads only, shows vertical wind component |
| Time
ticker |
, |
2C |
44 |
00101100 |
CPU |
count
of display channel time slices from CPU |
| |
- |
2D |
45 |
00101101 |
|
|
| |
. |
2E |
46 |
00101110 |
|
|
| |
/ |
2F |
47 |
00101111 |
|
|
| User
0 |
0 |
30 |
48 |
00110000 |
RS-232 |
[2]
polar interface also replies to queries on this tag |
| User
1 |
1 |
31 |
49 |
00110001 |
RS-232 |
[2] |
| User
2 |
2 |
32 |
50 |
00110010 |
RS-232 |
[2] |
| User
3 |
3 |
33 |
51 |
00110011 |
RS-232 |
[2] |
| User
4 |
4 |
34 |
52 |
00110100 |
RS-232 |
[2] |
| User
5 |
5 |
35 |
53 |
00110101 |
RS-232 |
[2] |
| User
6 |
6 |
36 |
54 |
00110110 |
RS-232 |
[2] |
| User
7 |
7 |
37 |
55 |
00110111 |
RS-232 |
[2] |
| User
8 |
8 |
38 |
56 |
00111000 |
RS-232 |
[2] |
| User
9 |
9 |
39 |
57 |
00111001 |
RS-232 |
[2] |
Synopsis
|
: |
3A |
58 |
00111010 |
1,2,3 |
001: record of sensor data before processing,
see Synopsis
T1<20.03: shows averaging settings for display |
| |
; |
3B |
59 |
00111011 |
|
|
| Target
angle (?) |
< |
3C |
60 |
00111100 |
T1
+ Polar |
|
| |
= |
3D |
61 |
00111101 |
|
|
| |
> |
3E |
62 |
00111110 |
|
|
| |
? |
3F |
63 |
00111111 |
|
|
| Remote
commands |
@ |
40 |
64 |
01000000 |
RS-232
or Lynx |
see Control |
| Windspeed
Apparent |
A |
41 |
65 |
01000001 |
2 |
|
| Windspeed
True |
a |
61 |
97 |
01100001 |
1,2 |
See True
Wind
|
| Boatspeed |
B |
42 |
66 |
01000010 |
1 |
|
| VMG |
b |
62 |
98 |
01100010 |
1,2 |
velocity
dead upwind, not to next mark |
| Heading |
C |
43 |
67 |
01000011 |
3 |
A
and B corrections using O17= and O18= on RS-232 |
| Wind
Direction |
c |
63 |
99 |
01100011 |
1,2,3 |
See True
Wind |
| Wind
Angle Apparent |
D |
44 |
68 |
01000100 |
2 |
|
| Wind
Angle True |
d |
64 |
100 |
01100100 |
1,2 |
See True
Wind |
| Mast
Angle |
E |
45 |
69 |
01000101 |
mast
rotation |
|
| Bt/Vt
correction |
e |
65 |
101 |
01100101 |
T1
+ 1,2 |
T1
only |
Current Set
Current Drift |
F
F' |
46 |
70 |
01000110 |
1,3,4 |
[1]
adjustments via O14= and O15= on RS-232 |
| VMC |
f |
66 |
102 |
01100110 |
1,4,5 |
Vmg on rhumbline to mark (see O10= and O11=) |
Air Temperature
Sea Temperature |
G
G' |
47 |
71 |
01000111 |
see
notes |
[1] units depend on system settings (set on O12=)
baro/temp or air temp from new sonic MHU, sea temp from NMEA depth xdcr |
Barometer Trend
Barometric Pressure |
g
g' |
67 |
103 |
01100111 |
see
notes |
[1] units depend on system settings (set on O12=)
baro/temp or new sonic MHU |
| Heel |
|
48 |
72 |
01001000 |
2
or 3a |
heel
on port tack is negative, on starboard is positive |
| Leeway |
h |
68 |
104 |
01101000 |
1,2 |
calculated
value |
| CAL
Boatspeed Master |
I |
49 |
73 |
01001001 |
1 |
default
is 1.00 |
| CAL
Boatspeed Offset |
i |
69 |
105 |
01101001 |
1 |
default
is 0.000 |
| CAL
Wind Angle Offset |
J |
4A |
74 |
01001010 |
1 |
default
is 0.0 |
| CAL
Windspeed |
j |
6A |
106 |
01101010 |
2 |
default
is 1.00 |
| CAL
Leeway |
K |
4B |
75 |
01001011 |
1 |
value
of 7.0 is nearly universal, see System Manual for details |
| CAL
Upwash |
k |
|
|
|
2 |
[1] |
| CAL
Upwash/Upwash Slope |
k |
6B |
107 |
01101011 |
2 |
default
Upwash is 0.00, default Upwash Slope is +0.395 |
| CAL
Upwash Slope |
k' |
|
|
|
2 |
[1] |
| LOG
Permanent |
L |
4C |
76 |
01001100 |
1 |
Not
implemented in 001 rev A16 |
| Log
Trip |
l |
6C |
108 |
01101100 |
1 |
Reset by control codes |
| Aux.
1 |
M |
4D |
77 |
01001101 |
|
usually
Loadcell 1, but many Q interfaces use this tag |
| Aux.
2 |
m |
6D |
109 |
01101101 |
|
many
Q interfaces use this tag |
| Aux.
3 |
N |
4E |
78 |
01001110 |
|
usually
Trim Angle, but many Q interfaces use this tag |
| Aux.
4 |
n |
6E |
110 |
01101110 |
|
many
Q interfaces use this tag |
| Opposite
Tack Course |
O |
4F |
79 |
01001111 |
1,2,3,4 |
For
001>16.2 & all T1, opposite track (i.e., includes
current). |
| Magnetic
Variation |
o |
6F |
111 |
01101111 |
4
or RS-232 |
GPS output or Calibration K7 |
| POLAR
Boatspeed |
P |
50 |
80 |
01010000 |
1,2,5 |
theoretical
speed for current true wind angle (also see O20=) |
| Target
Boatspeed |
p |
70 |
112 |
01110000 |
1,2,5 |
optimal
boatspeed for current true wind angle (also see O20=) |
| Time
to Starboard Layline |
Q |
51 |
81 |
01010001 |
1,2,3,4 |
MM:SS
format, may be positive or negative, upwind or downwind |
| Time
to Port Layline |
q |
71 |
113 |
01110001 |
1,2,3,4 |
MM:SS
format, may be positive or negative, upwind or downwind |
Waypoint Bearing
Waypoint Range |
R
R' |
52 |
82 |
01010010 |
1,3,4 |
[1]
can also be set via command (W=) on RS-232 |
Back Bearing
Back Range |
r
r' |
72 |
114 |
01110010 |
1,3 |
[1]
reset via ctrl+B on RS-232 |
| Status
Output |
S |
53 |
83 |
01010011 |
T1 |
T1
v.20.03 or higher, shows messages from sensors |
| |
s |
73 |
115 |
01110011 |
|
|
| Time
(of day) |
T |
54 |
84 |
01010100 |
CPU |
24
hour format; format adjustable (see Option 1) |
| Stopwatch |
t |
74 |
116 |
01110100 |
CPU |
Operated by control codes,
format
adjustable (Option 13) |
COG
SOG |
U
U' |
55 |
85 |
01010101 |
4 |
[1]
can be substituted for Boatspd & Hdg (see Option
16) |
| |
u |
75 |
117 |
01110101 |
|
|
Distance Lost Vs
Lift/Head |
V |
56 |
86 |
01010110 |
|
on 001
on T1 |
Distance Lost VMG
Puff/Lull |
v |
76 |
118 |
01110110 |
|
on 001
on T1 |
| Depth
Below Surface |
W |
57 |
87 |
01010111 |
depth |
units
depend on system settings (see Option 12) |
| Depth
Below Keel |
w |
77 |
119 |
01110111 |
depth |
units
depend on system settings (see Option 12) |
Latitude
Longitude |
X
X' |
58 |
88 |
01011000 |
4 |
[1]
shown in decimal degrees; formatted for computer use |
| Cross-track
error |
x |
78 |
120 |
01111000 |
4 |
T1
> 20.02 |
| Rudder
Angle |
Y |
59 |
89 |
01011001 |
rudder |
|
| Trim
Tab Angle |
y |
79 |
121 |
01111001 |
rudder |
|
Test Configuration
Firmware version |
Z
Z' |
5A |
90 |
01011010 |
CPU |
for 001 and T1: shows active interfaces on Ockam
bus, see System Manual
T1: alternates configuration/version; 001: displays version once at
startup |
| Test
Errors |
z |
7A |
122 |
01111010 |
CPU |
errors
and information codes from instrument system |
| |
[ |
5B |
91 |
01011011 |
|
|
| |
\ |
5C |
92 |
01011100 |
|
|
| |
] |
5D |
93 |
01011101 |
|
|
| Trim
(average pitch) |
^ |
5E |
94 |
01011110 |
trim
or 3a |
requires
either trim interface or compass with HPR output to proper interface |
| |
_ |
5F |
95 |
01011111 |
|
|
| |
` |
60 |
96 |
01100000 |
|
|
| |
{ |
7B |
123 |
01111011 |
|
|
| |
| |
7C |
124 |
01111100 |
|
|
| |
} |
7D |
125 |
01111101 |
|
|
| Sea
State |
~ |
7E |
126 |
01111110 |
trim
or 3a |
requires
either trim interface or compass with HPR output to proper interface |
| |
delete |
7F |
127 |
01111111 |
|
unprintable
"box" character (delete key) |
| 005
Remote Address 1 |
|
|
|
10000000 |
|
provides
remote control of B revision 005 displays – defaults to
boatspeed |
| 005
Remote Address 2 |
|
|
|
10000100 |
|
provides
remote control of B revision 005 displays – defaults to
stopwatch |
| 005
Remote Address 3 |
|
|
|
10100000 |
|
provides
remote control of B revision 005 displays – defaults to
windspeed true |
| 005
Remote Address 4 |
|
|
|
10100100 |
|
provides
remote control of B revision 005 displays – defaults to wind
direction |
| 005
Remote Address 5 |
|
|
|
11000000 |
|
provides
remote control of B revision 005 displays – defaults to wind
angle app. |
| 005
Remote Address 6 |
|
|
|
11000100 |
|
provides
remote control of B revision 005 displays – defaults to wind
angle true |
| 006
Remote Address 7 |
|
|
|
11100000 |
|
provides
remote control of B revision 005 displays – defaults to
heading |
| 005
Remote Address 8 |
|
|
|
11100100 |
|
provides
remote control of B revision 005 displays – defaults to
waypoint R/B |
| 005 card test |
|
FF |
255 |
11111111 |
|
Switches